Match the lot on your vial

A COA records what a laboratory measured in a submitted sample. Start with three details on your vial label and find each one on the report. The compound name, labeled amount and lot number should all match. Two vials with the same name and strength can come from different batches.

Check who issued the report

Find the laboratory name, report number and dates. The received date tells you when the sample arrived. The analysis date tells you when it was tested. Open the full report and use the issuing lab’s verification page and code when provided. If the lot or report number differs, ask for the matching document.

Read one result across the row

The analyte is what the lab measured. The method explains how it measured it. The specification gives the acceptance criterion. Compare the result and its units with that criterion. “Pass” applies to that test. “Report only” means the lab recorded a measurement without giving it a pass or fail.

Separate identity, purity and amount

Identity tells you which compound the test identified. HPLC purity describes the share of the measured peak area attributed to that compound among the peaks the method counts. Net content is the measured amount in milligrams. In the linked report, the label says 10 mg, the lab reports 10.29 mg of net peptide, and the purity result is 99.56%. Each number answers a different question.

Read the chromatogram

Time runs across the bottom of the graph. Detector response runs up the side. A peak forms as a component passes the detector. Use the legend to find the peak assigned to the peptide, then read the method notes to see which signals the lab included in the purity calculation.

Check which other tests were run

Look for individual rows for metals, endotoxins or microbial testing. Read “not detected” alongside the method and its detection limit. A missing test leaves that question open. The findings apply to the sample tested. A COA alone cannot establish safety for human use.